Testing
Galvanizing & testing of material shall confirm to the latest edition of following standards.
Recommended Practices for Hot Dip Galvanized of:
Acceptance Test:
Hot Dip Galvanizing:
610 gm of zinc per square meter surface with approximate thickness off 80 micron.Zinc coating should be smooth, clean and uniform thickness and free from defects like ash and dross inclusion, bare patches, black spots,pimples, lumpiness, rust stain blisters etc.
Quality of coating will be established by test as per IS-2633.
All manufacturing work including punching, cutting, bending and welding of cable trays will be completed and burrs shall be removed before application of galvanizing process. Zinc should confirm to at least Grade Zn98 as specified in IS 209-1966.